If your Henny Penny deep fryer is giving you errors such as “high limit tripped” or “low limit tripped,” it is probably time to get it fixed. Below are a few possible causes and solutions. Depending on the code, a technician may need to replace the unit or repair it.

Anúncios

Henny Penny deep fryer error codes

If you are having problems with your Henny Penny pressure fryer, you may need to check your electric supply box, reset the breaker or replace a fuse. It is also possible that the main power switch is defective. You should check the gas valve as well, to make sure it is in the on position.

If this is the case, refer to your manual to determine the cause. For example, the “E-15” error code may occur while the drain is closed but the oil is still coming out of the fryer. In this case, you should take it to an authorized technician and have it replaced.

Anúncios

The digital display will show error messages and may also have a constant beep. This is an indicator of a failure in the control system. To silence the beep, press the appropriate buttons on the product to silence it. A similar error may occur when the control panel becomes overheated. To fix this, turn the switch back on and let it cool down. If this does not solve the problem, it is recommended to replace the control board with a new one.

Error codes on Henny Penny deep fryers can indicate a number of problems. First, the unit may have not been filled with oil. It may also be dry-fired. It may need to be filled with oil and cooled for fifteen to twenty minutes. If this does not resolve the problem, you should contact a technician to fix the machine. Another cause of this error code is a tripped or blown fuse.

Henny Penny deep fryer high limit tripped

If you’ve noticed that your Henny Penny deep fryer’s high limit has been tripped, the first thing to do is check your manual. There are a number of possible reasons why the high limit of your machine has been tripped, including an overheating unit, low oil, or a dry-fired unit. If you’re unable to determine the cause of the error, you can contact an authorized technician for assistance.

Another possible cause of a high limit tripped Henny Penny fryer is a clogged deadweight or exhaust line. In either case, you’ll need to shut down the fryer and allow it to cool completely before you can try cooking again. If the pressure gauge continues to show a high limit, don’t operate or use the machine. If this problem is a recurring problem, it is best to consult an authorized service agent.

If the unit isn’t running, it may have a malfunctioning thermostat or thermal switch. You may need to replace a breaker or fuse. In some cases, a tripped thermal switch may indicate a faulty motor thermal protector. Resetting the thermal switch may fix the problem.

Henny Penny fryer low limit tripped

When the Henny Penny fryer is experiencing low oil levels, it will trip its high limit. This can happen for a variety of reasons. In some cases, the oil level may be too low or the unit could be dry-fired. In these cases, you need to contact an authorized technician for help. The first step in troubleshooting the problem is to make sure that the drain is closed.

Another possible cause of this problem is an open circuit. If the power switch is on but the motor is not running, the breaker or fuse may be faulty. The next step is to reset the high limit control. If this doesn’t work, you may have to replace the unit.

A pressure frying problem can also be caused by the fryer’s deadweight or exhaust line. If this occurs, you need to stop using the machine and allow it to cool completely. If the pressure gauge is high, you should stop using it and get a service agent to repair the unit.

If the power switch is on but the fryer is not working, then a breaker may have been tripped in the supply box or in the fryer itself. If so, reset the breaker by pressing the reset button on the controls on the right. If this doesn’t work, you’ll need to replace the high limit reset button. If the high limit reset button is still tripped, you’ll need to replace the high-temperature limit reset button.